<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-23 16-23-53
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
5.5 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 67 kHz 18534 0,9928
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,1 dBr 2,99 dBr 4,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 67 kHz MIN: 11 kHz % above 76 kHz: 0,9928 Acquired: 2024/10/23 16.22.50 Total samples: 18534 Equivalent time: 0:15:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,6 dBr MIN: 1,1 dBr AVE: 2,99 dBr % above 12,2 dBr: 0,0 Last value: 2,8 dBr (2024/10/23 16.22.50) 16.08 16.10 16.12 16.14 16.16 16.18 16.20 16.22 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]